Psion Teklogix netpad Windows CE .NET 4.2 User Manual 77
Chapter 4: Configuring The netpad
Bar Codes
DECODED SETTINGS
Xmit Check Digit
If this parameter is ON, the check digit is included with the decoded bar code data.
MSI Check Digits
Check digits at the end of a bar code verify the integrity of the data. If MSI Check
Digits is set to One, it is assumed that the last digit of the bar code is the check digit.
If the parameter is set to Two, it is assumed that the last two digits of the bar code
are the check digits. If Two is selected, Check Digit Algorithm must also be enabled.
Check Digit Algorithm
When MSI Check Digits is set to Two, an additional verification is required to
ensure integrity. The options are: Mod 10/Mod 11 or Mod 10/Mod 10.
Set Lengths
For the parameter settings in this menu, please refer to “Set Lengths” on page 66.
4.3.2.12 Discrete 2 Of 5
Figure 4.15 Discrete 2 Of 5 Bar Code Settings