Psion Teklogix 7527S Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Dokovací stanice mobilních zařízení Psion Teklogix 7527S. Psion Teklogix 7527S User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 42
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
NEW
V680 Series
RFID System
Next-Generation RFID System
Conforming to ISO/IEC 18000-3
(ISO/IEC 15693).
New ID Sensor Units
for CJ1/CS1 PLCs and New M12 Antenna.
Visualize data transmission on
production lines.
Managing the manufacture of LCDs
and color filters
Managing dies, die histories,
and die service lives
Managing process instructions
and histories for engine
manufacturing
Managing manufacturing process
traceability
Zobrazit stránku 0
1 2 3 4 5 6 ... 41 42

Shrnutí obsahu

Strany 1 - RFID System

NEWV680 SeriesRFID SystemNext-Generation RFID System Conforming to ISO/IEC 18000-3 (ISO/IEC 15693).New ID Sensor Units for CJ1/CS1 PLCs and New M12 An

Strany 2 - Use on Production Lines

10 V680 Series RFID SystemAccessories (Order Separately)ID Tag AttachmentAmplifier Unit Special Extension Cable (Amplifier Unit to Controller)V680-H01

Strany 3 - Simpler Operation

V680 Series RFID System 11Ratings and PerformanceID Tag (1-Kbyte Memory)Note 1. Refer to the User's Manual (Cat. No. Z262) for data backup time f

Strany 4 - Noise Level Measurement Mode

12 V680 Series RFID SystemHeat ResistanceSufficient heat resistance has been confirmed by evaluation testing comprising 2,000 thermal cycles each of 3

Strany 5 - Tag Communications Test Mode

V680 Series RFID System 13Cylindrical Read/Write Antenna (Detachable Amplifier Unit Type)Note 1. The degree of protection for the Connector is IP67/IP

Strany 6 - V680 Series

14 V680 Series RFID SystemSquare Read/Write Antenna with Built-in AmplifierNote 1. Use an Antenna Cable to connect the Read/Write Antenna to the Contr

Strany 7 - System Configuration

V680 Series RFID System 15ControllerNote: For details, refer to the User's Manual (Cat. No. Z249).ID Controller Communications SpecificationsID C

Strany 8 - Ordering Information

16 V680 Series RFID SystemID Sensor UnitsNote: When connected to the V680-H01: 280 mAFunctional Specifications of ID Sensor UnitsNote 1. Cannot be use

Strany 9 - V680 Series RFID System 9

V680 Series RFID System 17AC Adapter (for V680-CH1D)Host Communications Interface Specifications USB interfaceNote: Used as the COM port on the host d

Strany 10 - V680 Series RFID System

18 V680 Series RFID SystemHandheld Terminal AccessoriesName Appearance Size Psion Teklogix model number OMRON model numberHigh-capacity Battery 55 × 3

Strany 11 - Ratings and Performance

V680 Series RFID System 19 Ratings and SpecificationsPsion Teklogix Handheld TerminalNote: The Easy Access demonstration software is preinstalled on

Strany 12

Can be used in many countries around the world.Conforms to ISO/IEC 18000-3 (ISO/IEC 15693)High-speed transmission of 27 kbps achieved.The V680 Series

Strany 13 - V680 Series RFID System 13

20 V680 Series RFID System Performance SpecificationsID Tag (1-kbyte Memory) TransmissionNote 1. When mounting the V680-HS65, be sure to attach the M

Strany 14

V680 Series RFID System 21Recommended combination Function Transmission distance(unit: mm)ID Tag and Read/Write Antenna mounting conditionsID Tag Read

Strany 15 - ■ USB Port

22 V680 Series RFID SystemNote 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna.The enclosed Mountin

Strany 16

V680 Series RFID System 23ID Tag (2-kbyte Memory) TransmissionRecommended combination Function Transmission distance(unit: mm)ID Tag and Read/Write An

Strany 17 - V680 Series RFID System 17

24 V680 Series RFID SystemID Tag (8-/32-Kbyte Memory) TransmissionNote: When mounting the V680-HS65, be sure to attach the Mounting Brackets at the ba

Strany 18

V680 Series RFID System 25Handheld Reader Writer Communications SpecificationsNote: ID Tag Mounting Conditions• V680-D1KP52MT: Embedded in resin or st

Strany 19 - V680 Series RFID System 19

26 V680 Series RFID SystemV680-HS51 (embedded in metallic material) & V680-D1KP52MTV680-HS51 (embedded in metallic material) & V680-D1KP52MT (

Strany 20 - ■ Performance Specifications

V680 Series RFID System 27V680-HS65 (mounted on metallic material) & V680-D1KP66T-SPV680-HS52 (embedded in non-metallic material) & V680-D1KP6

Strany 21 - V680 Series RFID System 21

28 V680 Series RFID System2-kbyte Memory ID TagThe values given for communications ranges are reference values. Refer to pages 23 to 24 for communicat

Strany 22

V680 Series RFID System 29V680-HS52 (embedded in non-metallic material) & V680-D2KF67M (flush-mounted on metallic surface: steel)V680-HS63 (mounte

Strany 23 - V680 Series RFID System 23

Easier Startup and Maintenance. Simpler Operation.Contributes to higher efficiency for on-site startup and maintenance.Seven maintenance modes make it

Strany 24

30 V680 Series RFID System8-/32-Kbyte Memory ID TagThe values given for communications ranges are reference values. Refer to page 24 for communication

Strany 25 - Characteristic Data (Typical)

V680 Series RFID System 31Communications TimeCommunications Time between Antennas and Tags1-Kbyte Memory ID TagV680-D1KP@ (used in combination with th

Strany 26 - 26 V680 Series RFID System

32 V680 Series RFID SystemTAT When Using an ID Controller (Reference Values) TAT (Turn Around Time)TAT refers to the total time required from the poin

Strany 27 - V680 Series RFID System 27

V680 Series RFID System 332-Kbyte Memory ID TagV680-D2KF@@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63B Amplifier Unit)No

Strany 28 - 2-kbyte Memory ID Tag

34 V680 Series RFID System8-/32-Kbyte Memory ID TagV680-D8KF@@, V680-D32KF@@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63B

Strany 29 - V680 Series RFID System 29

V680 Series RFID System 35Safety PrecautionsNote: This catalog is intended only to help select the appropriate product. Be sure to read the User'

Strany 30 - 8-/32-Kbyte Memory ID Tag

36 V680 Series RFID SystemDimensionsNote: All units are in millimeters unless otherwise indicated.ID TagRead/Write Antenna with Detachable Amplifier U

Strany 31 - V680 Series RFID System 31

V680 Series RFID System 3712.5 dia.21 dia.17Toothed washerTwo mountingnuts71524332550Ferrite core26.2Coaxial cable, 2.9 dia., Standard length: 2 m359.

Strany 32

38 V680 Series RFID SystemRead/Write Antenna with Built-in Amplifier UnitAmplifier UnitID Controller4013.521200250235142.5857.520-mm max.50078.820-mm

Strany 33 - V680 Series RFID System 33

V680 Series RFID System 39ID Sensor UnitsHandheld Reader WriterCJ1W-V680C1165314.5(140)4.7Six operation indicatorsSwitchesConnector902.72.718.117.301C

Strany 34

Distant CloseLittle noise Much noiseMore than 99 successful communicationsVisualize Data Transmission without the Need for a Host Device. Perform Simp

Strany 35 - Safety Precautions

40 V680 Series RFID SystemAC Adapter Handheld Terminal (Recommended)AccessoriesV600-A2225.4±154±148±14+0.1 dia.9.5±0.32109042Recommended Handheld Term

Strany 36 - Dimensions

READ AND UNDERSTAND THIS DOCUMENTPlease read and understand this document before using the products. Please consult your OMRON representative if you h

Strany 37 - Mounting Hole Dimensions

2008.5OMRON CorporationIndustrial Automation Companyhttp://www.ia.omron.com/(c)Copyright OMRON Corporation 2008 All Rights Reserved. In the interest

Strany 38

Seven maintenance modes make it easy to diagnose the communications conditions from the front panel of the Controller or Amplifier Unit. The data can

Strany 39 - V680 Series RFID System 39

6 V680 Series RFID SystemRFID SystemV680 SeriesNew, Next-generation RFID Systems with ISO/IEC 18000-3 (ISO/IEC15693) Compliance• High-speed, 27-kbps

Strany 40

V680 Series RFID System 7System ConfigurationConnect V680 Read/Write Antennas and Amplifier Units to a V680-series Controller, and read or write data

Strany 41 - Regional Headquarters

8 V680 Series RFID SystemOrdering InformationID TagRead/Write Antenna (Detachable Amplifier Unit Type)Read/Write Antenna with Built-in AmplifierNote:

Strany 42 - OMRON Corporation

V680 Series RFID System 9Amplifier UnitNote: The maximum extendable cable length is 50 m (including the Amplifier Unit cable). The maximum number of V

Komentáře k této Příručce

Žádné komentáře